Ventilation Fan

Industry: HVAC

Application: Ventilation Fan

Problem: Large direct-driven ventilation fan wheel was mounted directly on the shaft. Previous "QD" bushing mount often cocked the fan hub inducing runout and resulted in fan vibration.

Solution: Trantorque GT ensures perpendicular mounting, meaning fan vibration was eliminated. Other benefits include:

  • Eliminate the cocking problems associated with a multiscrew connection
  • Allows secure and precise mounting of fan hub
  • Ease of installation — fan hub can be dismounted quickly
  • Precision machined unit (.001 T.I.R. concentricity) reduces runout

Send me a catalog.